Operational Performance & Retrofit Strategy

Performance gap diagnosis, calibrated digital twins, and costed retrofit pathways for existing buildings and portfolios.

Discipline
Building physics
Tools
IES-VE, AutoCAD, Revit
Standards
CIBSE TM54, ASHRAE Standard 211, GHG Protocol, CRREM Pathways

We turn metered data into a costed retrofit plan with clear ROI for every intervention

The biggest carbon savings are in the buildings we already have.

We bridge the gap between predicted and actual building performance, then develop the investment case for closing it. Starting with metered data analysis and calibrated digital twins, we identify where energy is being lost and test retrofit scenarios with quantified savings, carbon reductions, and payback periods.

The vast majority of buildings that will exist in 2050 have already been built. Buildings routinely consume 50-100% more energy than predicted at design stage. Decarbonising existing stock requires both accurate diagnosis and evidence-based investment planning. Without calibrated models, retrofit decisions are guided by assumption.

Method

Calibrated digital twins from metered data, testing retrofit scenarios with quantified ROI and carbon savings. The animation illustrates the method, not project data.

Process

  1. 01Performance Baseline
  2. 02Energy Audit
  3. 03Digital Twin
  4. 04Gap Analysis
  5. 05Retrofit Scenarios
  6. 06Investment Case

What the client gets

  • Calibrated model against metered data
  • Retrofit scenarios with energy and cost
  • Payback and carbon per measure
  • Sequenced decarbonisation pathway

How we work

Four stages, from the first scope conversation to support through delivery. Each ends with something the design team can act on.

  1. 01

    Audit the building

    Conduct ASHRAE Level 1 or 2 energy audit and establish the current performance baseline from metered data.

  2. 02

    Build the digital twin

    Build a calibrated energy model using TM54 methodology until it matches actual performance within ±5%.

  3. 03

    Test retrofit options

    Test multiple retrofit packages and rank by energy reduction, carbon impact, cost, and payback period.

  4. 04

    Cost the pathway

    Deliver a sequenced decarbonisation plan aligned to CRREM trajectories with clear ROI projections.

Close the performance gap and build the business case for retrofit

From metered data to investment plan, with evidence at every step

Discuss your project